ERO 6180

Request

Scanning head

AK ERO 6180

Interface

1 VPP

Reference mark signal

Square-wave pulse

Cutoff frequency –3 dB

200 kHz

Electrical connection

Cable 3 m with D-sub connector (male, 15-pin)

Cable length

30 m

Voltage supply

5 V DC ± 0.25 V

Current requirement

< 100 mA (without load)

Vibration 55 to 2 000 Hz

Shock 11 ms

200 m/s2 (EN 60 068-2-6)

400 m/s2 (EN 60 068-2-27)

Operating temperature

0 °C to 50 °C

Weight Scanning head

(approx.) Connector

Cable

6 g (without cable)

32 g

22 g/m

Graduated disk

TKN ERO 6100

Measuring standard

Chromium graduation on glass

Signal periods

4 096

Accuracy of graduation

± 10”

Position error per signal period1)

± 5”

Reference marks

One

Hub inside diameter

41 mm

Circular scale outside diameter

70 mm

Mech. permissible speed

3 500 min-1

Moment of inertia

50 x 10-6 kgm2

Permissible axial motion

0.1 mm

Protection EN 60 529

IP 00

Weight (approx.)

71 g

1) The position error within one signal period and the accuracy of the graduation result together in the encoder-specific error; for additional error through mounting and the bearing of the measured shaft, see Measuring accuracy