Training
Documentation
Inquiry
Memory
20 programs with a total of 2000 NC blocks; a program can consist of up to 1000 NC blocks
Input resolution and display step
Selectable via parameters, for encoders with 20 µm grating period: from 0.001 mm to 0.1 mm
Range of traverse
Max. ±10 000 mm
Error compensation
Linear or nonlinear axis error compensation
Data interfaces
RS-232-C/V.24
Axes
3 closed-loop axes1 open-loop axis (for position display)
Accessory
Electronic handwheel
Power consumption (approx.)
27 W
Weight (approx.)
6.5 kg